Cloroflex

Cloroflex

pdf-icon

Code: 2U & 2V

Chlorinated-rubber based enamel modified with chemically inert resins. Provides excellente resistance to condensation water and to weather exposure also in particularly aggressive chemical environments.

SURFACE PREPARATION AND APPLICATION

New surfaces. Substrate should be free from rust, clean, dry and well degreased. Apply a first coat of suitable primer (e.g. ESSE-ENNE or EPOFOND AM-9). Apply 2 coats of CLOROFLEX allowing the required waiting time between coats.

Painted surfaces. If the exhisting paint are loose or powdery should be mechanically removed. Clean the surface and follow instructions as per new surfaces. If the old paint is in sound conditions, just sandpaper and apply 2 coats of CLOROFLEX allowing the required waiting time between coats.

Paint Type One component
Binder type A Chlorinated-alkyd
Specific gravity kg/lt (±0,05) 1.100-1.250 according to colour
Solids content (weight) ±2 58%
Viscosity Ford ø 8 at 20°C ±2 18-20
Shelf life +23°C (±2) 24 months in unopened cans
Application Brush-Roller-Spray
Brush-Roller 10-20 Thinner Nitro 723
Spray 15-30% Nitro Thinner 723
Recoat time 12-24 h
Application temperature Between +10 C and +40 C
Relevant humidity Less than 80%
Dry film thickness advised 40 microns per coat
Theoret. coverage m2/Lt 6-8

Colors: TINTE RAL OSSIDE
Color code: 2U0000

Colors: TINTE RAL BASI
Color code: 2V0000

SAFETY PRECAUTIONS

Before starting paint application please carefully read all the safety precautions indicated on the label of each can or in the product safety data sheet available on request. For further information please do not hesitate to contact our technical staff.



NOTES

The above information is given to the best of our current knowledge, however, because the conditions of use of our products are beyond our control, no warranty is given or to be implied in respect of such information. Our technical staff can be contacted to study customer's specific requirements involving our products in order to enable their most effective use. Dilution rates and drying times must be considered only indicative, mainly related to a temperature of 20 ° C (68°F) and may vary according to prevailing temperature, in presence of particular weather conditions or depending on application procedures.