RS2311

RS2311

pdf-icon

Code: 2O & 2P

Fast drying, alkyd based enamel providing outstanding gloss, flexibility, water resistance and tough film. Recommended use for metal shelves, agricultural vehicles, ground remote machinery, building tools, road trailers and chassis, industrial machinery,etc

SURFACE PREPARATION AND APPLICATION SYSTEM

Steel.

Bare surface: Apply a suitable primer. Overcoat with 1-2 coats of RE 2311 enamel and let dry.

Previously coated surfaces: Remove any loose or powdery paint. Touch up where necessary with a suitable primer. Overcoat with 1-2 coats of RE 2311 enamel  and let dry.

Paint Type One component
Binder type A Alkyd
Specific gravity kg/lt (±0,05) 1.150 depending on colour
Solids content (weight) ±2 65%
Viscosity Ford ø 8 at 20°C ±2 16-18 sec.
Shelf life +23°C (±2) 30 months in unopened cans
Application Brush-Roller-Spray
Brush-Roller 5-10% Nitro Thinner 723, (Roller for touch ups only)
Spray 15-25% Nitro Thinner 723
Dust dry 15-30 minutes (20c)
Recoat time 6-8 h
Application temperature Between +10 C and +40 C
Relevant humidity Less than 80%
Dry film thickness advised 40 microns per coat
Theoret. coverage m2/Lt 8-10

Colors: TINTE RAL OSSIDE
Color code: 2O0000

Colors: TINTE RAL FORTI
Color code: 2P0000

SAFETY PRECAUTIONS

Before starting paint application please carefully read all the safety precautions indicated on the label of each can or in the product safety data sheet available on request. For further information please do not hesitate to contact our technical staff.



NOTES

The above information is given to the best of our current knowledge, however, because the conditions of use of our products are beyond our control, no warranty is given or to be implied in respect of such information. Our technical staff can be contacted to study customer's specific requirements involving our products in order to enable their most effective use. Dilution rates and drying times must be considered only indicative, mainly related to a temperature of 20 ° C (68°F) and may vary according to prevailing temperature, in presence of particular weather conditions or depending on application procedures.