SURFACE PREPARATION AND APPLICATION
Bare steel. The substrate should be clean, dry, degreased and free from corrosion. Apply a first coat of suitable primer. Overcoat with 1 coat of SYNTHETIC FAST DRYING ENAMEL (RE).
Painted surfaces. If the old paint is in poor condition, remove any loose or powdery parts by mechanical wirebrush or sanding disk and sandpaper the surface. Touch up where required with suitable primer. Overcoat with 1 coat of SYNTHETIC FAST DRYING ENAMEL (RE). If the old paint is still in good conditions of adhesion and compatible, in that case apply directly 1-2 coats of SYNTHETIC FAST DRYING ENAMEL (RE)
Paint Type | One component |
Binder type A | Alkyd |
Specific gravity kg/lt (±0,05) | 1.100 |
Solids content (weight) ±2 | 48% |
Shelf life +23°C (±2) | 30 months in unopened cans |
Viscosity Ford (Ø4 a 20°C) | 130-160 sec. |
Application | Brush-Roller-Spray |
Brush-Roller | 5-15% Thinner 400 |
Spray | 15-25% Thinner 900 |
Dust dry | 15-30 minutes (20c) |
Recoat time | 12-24 h |
Application temperature | Between +10 C and +40 C |
Relevant humidity | Less than 80% |
Dry film thickness advised | 40 dry microns |
Theoret. coverage m2/Lt | 7-8 m2/Kg |
Colour mixing by weight | 75 parts ofi Neutral base with 25 parts of Colourants |
Colors: NEUTRO
Color code: 2LNE
Before starting paint application please carefully read all the safety precautions indicated on the label of each can or in the product safety data sheet available on request. For further information please do not hesitate to contact our technical staff.
The above information is given to the best of our current knowledge, however, because the conditions of use of our products are beyond our control, no warranty is given or to be implied in respect of such information. Our technical staff can be contacted to study customer's specific requirements involving our products in order to enable their most effective use. Dilution rates and drying times must be considered only indicative, mainly related to a temperature of 20 ° C (68°F) and may vary according to prevailing temperature, in presence of particular weather conditions or depending on application procedures.